Skip to main content

Power Electronics and Energy Systems · Inverters, PWM, and three-phase conversion

A separately excited DC machine is driven from a stiff DC bus V_dc=300 V by a bipolar…

Problem

Power Electronics and Energy Systems practice problem

A separately excited DC machine is driven from a stiff DC bus Vdc=300 VV_{\mathrm{dc}}=300\,\mathrm{V} by a bipolar PWM H-bridge. The armature back-EMF is E=240 VE=240\,\mathrm{V} and the armature resistance is Ra=0.5 ΩR_a=0.5\,\Omega. Armature inductance may be neglected in the PWM-period average. The machine is generating: a regenerative current I=20 AI=20\,\mathrm{A} flows from the motor into the bridge. Switching loss is neglected, so the bridge is an average power-conserving voltage transformer from bus to armature.

Bipolar PWM applies +Vdc+V_{\mathrm{dc}} for duty dd of each carrier period and −Vdc-V_{\mathrm{dc}} for the complementary interval, so the average armature voltage isVa=(2d−1)Vdc.V_a=(2d-1)V_{\mathrm{dc}}.With the stated generating current, Kirchhoff's voltage law on the armature is E=Va+IRaE=V_a+I R_a.

1. Prove Va=E−IRa=230 VV_a=E-I R_a=230\,\mathrm{V}. Invert the bipolar map and
proved=5360=0.883333.d=\frac{53}{60}=0.883333.2. Prove the mechanical conversion EI=4.8 kWE I=4.8\,\mathrm{kW}, the copper
loss I2Ra=200 WI^2 R_a=200\,\mathrm{W}, and the power returned at the armature terminals VaI=4.6 kWV_a I=4.6\,\mathrm{kW}. Confirm the ledger
4.8 kW−200 W=4.6 kW4.8\,\mathrm{kW}-200\,\mathrm{W}=4.6\,\mathrm{kW}.

3. Prove that the average current returned into the 300 V300\,\mathrm{V}
bus isIbus=4.6 kW300 V=15.3333 A.I_{\mathrm{bus}}=\frac{4.6\,\mathrm{kW}}{300\,\mathrm{V}} =15.3333\,\mathrm{A}.4. Audit both sentences: (i) “regeneration requires Va<0V_a<0, hence
d<1/2d<1/2”; (ii) “the bus current equals the armature current 20 A20\,\mathrm{A}, or else Va=E+IRa=250 VV_a=E+I R_a=250\,\mathrm{V}.”

Do not replace the average bipolar map by a hard-switching conduction / transition / recovery loss ledger, do not invoke three-phase SVPWM sector dwell, and do not discuss transformer reset or flux walk.

Hint

Hint

Generating KVL is Va=240−20⋅0.5V_a=240-20\cdot 0.5, not 240+10240+10. The result is still well above zero.

Check your work

Work the problem yourself first. Then open it in Training to check your answer and read the full worked solution.

The answer check and full solution for this problem come with ProofAnvil Practice membership ($19 USD monthly). See membership. Or start with the free Power Electronics and Energy Systems sample problem: Try the free sample problem.